Application Notes
Description : Ethylene diamine (EDA) Scrubber
Process Flow Diagram

Process Description
As per environmental regulations, Ethylene di-amine (EDA) in vent gases should be <10 ppm (<25mg/m3). The process gas from various streams is collected and treated with water to scrub EDA to the desired specification level. The system has to be design for various EDA fluctuating loads in the plant. The sizes of these columns are reasonably high, ranging from 2-4 m in diameters, since these column handle vent gases produced in entire plant.

Operating Conditions
EDA scrubbers are operated with wide range of process conditions
•  Pressure : 1.1-5 bar
•  Temperature : 40-120 0 C